"P" - PAIRED PANEL OPERATION
Easiest operation, but straight runs only, no turns.
Supported from above, with no weight on the floor.
Panels hinged in pairs, in even numbers only.
Panels are stacked centered on the track, at either, or both ends of the run.
The panels can be stored in a pocket, with or without pocket doors.
"S" - SINGLE PANEL OPERATION
The most flexibility as the panels can turn corners.
Supported from above, with no weight on the floor.
Each panel is individual, with two trolleys.
Panels are stacked to one side of the track, or in a remote location.
The panels can be stored in a pocket, with or without pocket doors.
"E" - ELECTRIC OPERATION
Easiest operation, but more expensive and straight runs only, no turns.
Supported from above, with no weight on the floor.
Panels are all hinged together to make a train, in odd numbers only.
Panels are stacked centered on the track, at either, or both ends of the run.
The panels can be stored in a pocket, with or without pocket doors.
"G" - ELECTRIC GYM WALL OPERATION
Designed for use in School Gymnasiums, straight runs only, no turns.
Supported from above, with no weight on the floor.
Panels are all hinged together to make a train, in odd numbers only.
Panels are stacked centered on the track, at either, or both ends of the run.
The panels can be stored in a pocket, with or without pocket doors.
"ST" - FLOOR SUPPORTED SINGLE PANEL OPERATION
Special design for installations where overhead support is not available.
The weight of the panels shifts to the floor when parked.
Each panel is individual, with two trolleys.
Panels are stacked to one side of the track, or in a remote location.
The panels can be stored in a pocket, with or without pocket doors.
TYPE "A" PANEL CONSTRUCTION
Least expensive.
Paired or Single panels with sweep seals only.
Welded steel frame, bonded standard MDF / PB face.
STC 49 to ASTM E90-90
Maximum height - 10' or 3050mm
Maximum width - 54" or 1370mm
Weight - 7 lbs. / sq. ft., or 29 kg. / sq. mtr.
TYPE "B" PANEL CONSTRUCTION
Medium cost.
Available for all operations.
Welded steel frame, bolted MDF / PB face.
STC 49 to ASTM E90-90
Maximum height - none
Maximum width - 54" or 1370mm
Weight - 8 lbs. / sq. ft., or 39 kg. / sq. mtr.
TYPE "C" PANEL CONSTRUCTION
Moderate cost.
Available for all operations.
Welded steel frame, 21-26 gage steel liner, bolted MDF / PB face.
STC 52 to ASTM E90-90
Maximum height - none
Maximum width - 54" or 1370mm
Weight - 10 lbs. / sq. ft., or 49 kg. / sq. mtr.
TYPE "D" PANEL CONSTRUCTION
Most expensive.
Available for all operations.
Welded steel frame, 21-26 gage steel face.
STC 54 to ASTM E90-90
Maximum height - none
Maximum width - 48" or 1235mm
Weight - 10 lbs. / sq. ft., or 49 kg. / sq. mtr.
"P" - PAINT FINISH
Least expensive.
Factory primed only, to be finished on site.
Unbreakable PVC trim protects all edges.
"V" - VINYL FINISH
Class "A" rated heavy duty vinyl finish.
Reinforced woven backing.
Unbreakable PVC trim protects all edges.
"C" - ACOUSTIC CARPET FINISH
Acoustical Wall Carpet.
Non-woven, fused fibre, Class "A" rated.
Unbreakable PVC trim protects all edges.
"F" - WALL COVERING FABRIC FINISH
Polyolefin Wall Fabric.
Teflon coated, Class "A" rated.
Unbreakable PVC trim protects all edges.
"M" - MELAMINE FINISH
High pressure laminated melamine board.
Class "A" rated.
Unbreakable PVC trim protects all edges.
"L" - PLASTIC LAMINATE FINISH
High pressure plastic laminate.
Class "A" rated.
Unbreakable PVC trim protects all edges.
"W" - NATURAL WOOD FINISH
Natural wood veneer.
Can be treated to achieve a Class "A" rating.
Unbreakable PVC trim protects all edges.
"O" - OWNER SUPPLIED FINISH
Owner supplied finish material.
Installed at the factory.
Subject to factory approval.
"S" - SPECIAL FINISH DETAILS
Mirrors, glass, chair rails, etc.
TYPE "1" SOUND SEALS
1" Sweep top seal.
1" Sweep bottom seal.
Soft bulb lead nose and expandable jamb.
Allowable deflection or floor variation - .25"
SINGLE PANELS ONLY
TYPE "2" SOUND SEALS
1" Sweep top seal.
2.5" Sweep bottom seal.
Soft bulb lead nose and expandable jamb.
Allowable deflection or floor variation - 1.25"
TYPE "3" SOUND SEALS
1" Sweep top seal.
1.5" Mechanical bottom seal.
Soft bulb lead nose and expandable jamb.
Allowable deflection or floor variation - .75"
TYPE "4" SOUND SEALS
1" Sweep top seal.
2.5" Mechanical bottom seal.
Soft bulb lead nose and expandable jamb.
Allowable deflection or floor variation - 1.25"
TYPE "5" SOUND SEALS
1" Mechanical top seal.
1.5" Mechanical bottom seal.
Soft bulb lead nose and expandable jamb.
Allowable deflection or floor variation - .75"
TYPE "6" SOUND SEALS
1" Mechanical top seal.
2.5" Mechanical bottom seal.
Soft bulb lead nose and expandable jamb.
Allowable deflection or floor variation - 1.25"
TYPE "7" SOUND SEALS
1" Sweep top seal.
2.5" Floating mechanical bottom seal.
Soft bulb lead nose and expandable jamb.
Allowable deflection or floor variation - 1.25"
ELECTRIC OR GYM WALLS ONLY
TYPE "S" SUSPENSION
PAIRED PANELS, STRAIGHT RUNS, 11' OR LESS
Track - Heat treated, tempered, anodized aluminum.
Trolley - 4 Wheeled, nylon tired precision sealed bearings.
Support - Rods to steel, Rods to concrete, or Direct-mount.
TYPE "P" SUSPENSION
PAIRED OR ELECTRICS, STRAIGHT RUNS, 11' AND OVER
Track - Heat treated, tempered, anodized aluminum.
Trolley - 4 Wheeled, nylon tired precision sealed bearings.
Support - Rods to steel, Rods to concrete, or Direct-mount.
TYPE "R" SUSPENSION
SINGLE PANELS ONLY, 11' OR LESS
Track - Heat treated, tempered, anodized aluminum.
Trolley - 1 Wheeled omni-directional, nylon tired precision sealed bearing.
Support - Rods to steel, Rods to concrete, or Direct-mount.
TYPE "O" SUSPENSION
SINGLE PANELS ONLY, 11' AND OVER
Track - Heat treated, tempered, anodized aluminum.
Trolley - 2 Wheeled omni-directional, nylon tired precision sealed bearings.
Support - Rods to steel, Rods to concrete, or Direct-mount.
TYPE "H" SUSPENSION
PAIRS, SINGLES, OR ELECTRICS, 16' AND OVER
Track - Heavy duty 3" "I" Beam.
Trolley - 4 Steel-wheeled, steel tired with precision sealed bearings.
Support - Bracket-mount rods to steel or concrete.
TYPE "G" SUSPENSION
GYM WALLS ONLY
Track - Heavy duty 5" "I" Beam.
Trolley - 4 Steel-wheeled, steel tired with precision sealed bearings.
Support - Bracket-mount rods to steel or concrete.
"L-49" (STC 49) SOUND RATING
"A" - "B" - "C" Panels only
Lab sound test to STC 49
ASTM E90-90
ISO 140/111 1978(E)
ASTM 413-94
ISO 717
MUST BE INSTALLED TO ASTM E556
"L-52" (STC 52) SOUND RATING
"C" - "D" Panels only
Lab sound test to STC 52
ASTM E90-90
ISO 140/111 1978(E)
ASTM 413-94
ISO 717
MUST BE INSTALLED TO ASTM E556
"L-54" (STC 54) SOUND RATING
"D" Panels only
Lab sound test to STC 54
ASTM E90-90
ISO 140/111 1978(E)
ASTM 413-94
ISO 717
MUST BE INSTALLED TO ASTM E556
remove this item
000
TYPE "PS" POCKET DOOR
Sound rated pocket doors.
The same construction and sound seals as the panels.
Finished to match the panels.
remove this item
000
TYPE "PO" POCKET DOOR
Non-sound rated (or sound rated) pocket doors.
The same construction as the panels.
Finished to match the finishes used in the room.
Sound-seals installed where a rating is necessary.
remove this item
000
TYPE "MH" - HEAVY DUTY MAN DOOR
Sound rated pass door.
The same construction as the panels.
Finished to match the panels.
Sweep bottom seals.
Width - 12" less than the panel.
Height - 7'-0"
The pull and roller-latch hardware meets fire-exit codes.
Optional retractable threshold.
Optional exit sign.
remove this item
000
TYPE "MA" - ADA COMPLIANT MAN DOOR
Sound rated pass door.
The same construction as the panels.
Finished to match the panels.
Sweep bottom seals.
Width - Minimum ADA clear width of 32"
Height - 7'-0"
The pull and roller-latch hardware meets fire-exit codes and ADA.
Optional retractable threshold.
Optional exit sign.
remove this item
000
"CB" - CHALKBOARD
Porcelain steel chalk board built into the face of the panel.
Typically 48" high x full width of the panel.
Flush trim with no exposed fasteners.
A flush mounted chalk tray is available as an option.
remove this item
000
"MB" - MARKERBOARD
Porcelain steel marker board built into the face of the panel.
Typically 48" high x full width of the panel.
Flush trim with no exposed fasteners.
A flush mounted chalk tray is available as an option.
remove this item
000
"TB" - TACKBOARD
Natural cork tackboard built into the face of the panel.
Typically 48" high x full width of the panel.
Flush trim with no exposed fasteners.
Vinyl covering is available as an option.
remove this item
000
"VB" - VINYL BOARD
Vinyl covered cork tackboard built into the face of the panel.
Typically 48" high x full width of the panel.
Flush trim with no exposed fasteners.
Vinyl finish to match panels.