SELECT - "OPERATION"
Back Current selection = Skip
Model #
remove this item
000

"P" - PAIRED PANEL OPERATION

The operation shall be Type "P", a series of manually operated, top supported, center stacked, paired panels.

"S" - SINGLE PANEL OPERATION

The operation shall be Type "S", a series of manually operated, top supported, side stacked, or remote stacked, single panels.

"E" - ELECTRIC OPERATION

The operation Type "E", a series of electrically operated, top supported, center stacked, continuously hinged panels.

"G" - ELECTRIC GYM WALL OPERATION

The operation shall be Type "G", a series of electrically operated, top supported, center stacked, continuously hinged Gymnasium Divider panels.

"ST" - FLOOR SUPPORTED SINGLE PANEL OPERATION

The operation shall be Type "ST", a series of manually operated, top supported, side stacked, single panels that rest on the floor except when being relocated. The overhead track shall support only 1 panel at any time.

"CAUTION": No floor track shall be required, or, permitted.

TYPE "A" PANEL CONSTRUCTION

The panel construction shall be Type"A", 80 mm (3.15") thick, full height, one-piece construction, and of uniform equal widths not exceeding the width of the specified panel finish.

The structural steel tube sub-frame, and solid steel trolley attachments, shall be a completely welded self-supporting, rigid assembly.

The panel face shall be puncture & dent proof HD or MDF board, bonded to the frame to form a rigid unit.

"CAUTION": unequal panel widths, spliced panels, field joints, gyproc faces, or panels that twist or flex will not be accepted.

TYPE "B" PANEL CONSTRUCTION

The panel construction shall be Type"B", 80 mm (3.15") thick, full height, one-piece construction, and of uniform equal widths not exceeding the width of the specified panel finish.

The structural steel tube frame, and solid steel trolley attachments, shall be a completely welded self-supporting, rigid assembly.

The panel face shall be puncture & dent proof HD or MDF board, and shall be bolted to the steel tube frame at not more than 12" (300) c/c.

"CAUTION": unequal panel widths, spliced panels, field joints, bent metal or aluminum frames, bolted frame construction, non-welded trolley mounts, glued-on gyproc faces, or panels that twist or flex will not be accepted.

TYPE "C" PANEL CONSTRUCTION

The panel construction shall be Type"C", 80 mm (3.15") thick, full height, one-piece construction, and of uniform equal widths not exceeding the width of the specified panel finish material.

The structural steel tube frame, and solid steel trolley attachments, shall be a completely welded self-supporting, rigid assembly.

The panel face shall be puncture & dent proof HD or MDF board, and shall be bolted to the steel tube frame at not more than 12" (300) c/c.

The panel backing, shall be 26 - 21 gage, galvanized, sheet steel.

"CAUTION": unequal panel widths, spliced panels, field joints, bent metal or aluminum frames, bolted frame construction, non-welded trolley mounts, glued-on gyproc faces, or panels that twist or flex will not be accepted.

TYPE "D" PANEL CONSTRUCTION

The panel construction shall be Type"D", 80 mm (3.15") thick, full height, one-piece construction, and of uniform equal widths not exceeding 48" (1220), or the width of the specified panel finish.

The structural steel tube frame, and solid steel trolley attachments, shall be a completely welded self-supporting, rigid assembly.

The panel backing shall be puncture & dent proof HD or MDF board, and shall be bolted to the steel tube frame at not more than 12" (300) c/c.

The panel face shall be 21 - 26 gage, satin-coated or galvanized, stretcher leveled, sheet steel.

"CAUTION": unequal panel widths, spliced panels, field joints, bent metal or aluminum frames, bolted frame construction, non-welded trolley mounts, glued-on gyproc faces, or panels that twist or flex will not be accepted.

"P" - PAINT FINISH

The panel finish shall be Type "P", factory applied paint to the Architect or Owner's specifications.

The panel finish shall be protected on all edges by wrap around, solid color, un-breakable PVC trim.

"CAUTION": plastic or metal trim with a surface coating only, or trim-less panels will not be accepted.

"V" - VINYL FINISH

The panel finish shall be Type "V", factory applied, heavy duty, reinforced, woven back, class "A" rated vinyl, selected from the standard selector card.

The panel finish shall be protected on all edges by wrap around, solid color, un-breakable PVC trim.

"CAUTION": plastic or metal trim with a surface coating only, or trim-less panels will not be accepted.

"C" - ACOUSTIC CARPET FINISH

The panel finish shall be Type "C", factory applied, acoustical, non woven, fused fiber, class "A" rated carpet, selected from the standard carpet selector card.

The panel finish shall be protected on all edges by wrap around, solid color, un-breakable PVC trim.

"CAUTION": plastic or metal trim with a surface coating only, or trim-less panels will not be accepted.

"F" - WALL COVERING FABRIC FINISH

The panel finish shall be Type "F", factory applied, teflon coated, acrylic backed, class "A" rated, polyolefin wall covering and upholstery fabric, selected from the standard Operable Partition fabric selector card.

The panel finish shall be protected on all edges by wrap around, solid color, un-breakable PVC trim.

"CAUTION": plastic or metal trim with a surface coating only, or trim-less panels will not be accepted.

"M" - MELAMINE FINISH

The panel finish shall be Type "M", factory applied, high pressure laminated, class "A" rated, melamine board, selected from the standard melamine selector card.

The panel finish shall be protected on all edges by wrap around, solid color, un-breakable PVC trim.

"CAUTION": plastic or metal trim with a surface coating only, or trim-less panels will not be accepted.

"L" - PLASTIC LAMINATE FINISH

The panel finish shall be Type "L", factory applied, high pressure, heavy duty, class "A" rated, plastic laminate, selected from the standard laminate selector card.

The panel finish shall be protected on all edges by wrap around, solid color, un-breakable PVC trim.

"CAUTION": plastic or metal trim with a surface coating only, or trim-less panels will not be accepted.

"W" - NATURAL WOOD FINISH

The panel finish shall be Type "W", factory applied, natural wood veneer, selected from the manufacturer's selector cards, or as specified by the Architect or Owner.

The panel finish shall be protected on all edges by wrap around, solid color, un-breakable PVC trim.

"CAUTION": plastic or metal trim with a surface coating only, or trim-less panels will not be accepted.

"O" - OWNER SUPPLIED FINISH

The panel finish shall be Type "O", the owner’s own materials (subject to approval by the manufacturer), installed at the factory.

The panel finish shall be protected on all edges by wrap around, solid color, un-breakable PVC trim.

"CAUTION": plastic or metal trim with a surface coating only, or trim-less panels will not be accepted.

"S" - SPECIAL FINISH DETAILS

The panel finish shall be Type "S", special finish detailed as follows; _____________, installed at the factory.

The panel finish shall be protected on all edges by wrap around, solid color, un-breakable PVC trim.

"CAUTION": plastic or metal trim with a surface coating only, or trim-less panels will not be accepted.

TYPE "1" SOUND SEALS

The sound seals shall be Type"1". The lead nose and expandable closure shall seal to the wall with an extruded soft vinyl, compressible bulb seal.

The vertical seals between panels shall interlock a minimum of 50mm (2") by means of unbreakable, scratch and dent proof, solid color, self aligning, PVC tongue and groove extrusions.

The horizontal top seal shall be two continuous-contact, multi-finger, 25mm (1") vinyl sweep seals.

The horizontal bottom seal shall be, two, continuous-contact, multi-finger, 25mm (1") vinyl sweep seals.

"CAUTION": vertical wall jambs, swing closures, interlock of less than 50mm (2") between panels, or bottom seals of less than 25 mm (1") will not be accepted.

TYPE "2" SOUND SEALS

The sound seals shall be Type"2". The lead nose and expandable closure shall seal to the wall with an extruded soft vinyl, compressible bulb seal.

The vertical seals between panels shall interlock a minimum of 50 mm (2") by means of unbreakable, scratch and dent proof, solid color, self aligning, PVC tongue and groove extrusions.

The horizontal top seal shall be two continuous contact, multi-finger, 25 mm (1") vinyl sweep seals.

The horizontal bottom seal shall be, two, continuous- contact, multi-finger, 60 mm (2.5") vinyl sweep seals.

"CAUTION": vertical wall jambs, swing closures, interlock of less than 50mm (2") between panels, or bottom seals of less than 50 mm (2.5") will not be accepted.

TYPE "3" SOUND SEALS

The sound seals shall be Type"3". The lead nose and expandable closure shall seal to the wall with an extruded soft vinyl, compressible bulb seal.

The vertical seals between panels shall interlock a minimum of 50 mm (2") by means of unbreakable, scratch and dent proof, solid color, self aligning, PVC tongue and groove extrusions.

The horizontal top seal shall be two continuous contact, multi-finger, 25 mm (1") vinyl sweep seals.

The operable floor seal shall be a mechanical-retractable bottom seal providing 30 mm (1.2") operating clearance. Downward seal pressure shall provide maximum acoustical seal and stabilize the bottom of the partition.

"CAUTION": vertical wall jambs, swing closures, interlock of less than 50mm (2") between panels, or bottom seals allowing for less than 30 mm (1.2") of operating clearance will not be accepted.

TYPE "4" SOUND SEALS

The sound seals shall be Type"4". The lead nose and expandable closure shall seal to the wall with an extruded soft vinyl, compressible bulb seal.

The vertical seals between panels shall interlock a minimum of 50 mm (2") by means of unbreakable, scratch and dent proof, solid color, self aligning, PVC tongue and groove extrusions.

The horizontal top seal shall be two continuous contact, multi-finger, 25 mm (1") vinyl sweep seals.

The operable floor seal shall be a mechanical-retractable bottom seal providing 60 mm (2.5") operating clearance. Downward seal pressure shall provide maximum acoustical seal and stabilize the bottom of the partition.

"CAUTION": vertical wall jambs, swing closures, interlock of less than 50mm (2") between panels, or bottom seals allowing for less than 60 mm (2.5") of operating clearance will not be accepted.

TYPE "5" SOUND SEALS

The sound seals shall be Type"5". The lead nose and expandable closure shall seal to the wall with an extruded soft vinyl, compressible bulb seal.

The vertical seals between panels shall interlock a minimum of 50 mm (2") by means of unbreakable, scratch and dent proof, solid color, self aligning, PVC tongue and groove extrusions.

The operable head seal shall be a mechanical-retractable top seal providing 25 mm (1") operating clearance, and no resistance to movement of the panel. Upward seal pressure shall provide maximum acoustical seal and lock the panel in position when required.

The operable floor seal shall be a mechanical-retractable bottom seal providing 30 mm (1.2") operating clearance. Downward seal pressure shall provide maximum acoustical seal and stabilize the bottom of the partition.

"CAUTION": vertical wall jambs, swing closures, interlock of less than 50mm (2") between panels, sweep top seals, or bottom seals allowing for less than 30 mm (1.2") of operating clearance will not be accepted.

TYPE "6" SOUND SEALS

The sound seals shall be Type"6". The lead nose and expandable closure shall seal to the wall with an extruded soft vinyl, compressible bulb seal.

The vertical seals between panels shall interlock a minimum of 50 mm (2") by means of unbreakable, scratch and dent proof, solid color, self aligning, PVC tongue and groove extrusions.

The operable head seal shall be a mechanical-retractable top seal providing 25 mm (1") operating clearance, and no resistance to movement of the panel. Upward seal pressure shall provide maximum acoustical seal and lock the panel in position when required.

The operable floor seal shall be a mechanical-retractable bottom seal providing 60 mm (2.5") operating clearance. Downward seal pressure shall provide maximum acoustical seal and stabilize the bottom of the partition.

"CAUTION": vertical wall jambs, swing closures, interlock of less than 50mm (2") between panels, sweep top seals, or bottom seals allowing for less than 60 mm (2.5") of operating clearance will not be accepted.

TYPE "7" SOUND SEALS

The sound seals shall be Type"7". The lead nose and expandable closure shall seal to the wall with an extruded soft vinyl, compressible bulb seal.

The vertical seals between panels shall interlock a minimum of 50 mm (2") by means of unbreakable, scratch and dent proof, solid color, self aligning, PVC tongue and groove extrusions.

The horizontal top seal shall be two continuous contact, multi-finger, 25 mm (1") vinyl sweep seals.

The operable floor seal shall be a mechanical-floating bottom seal to compensate for 60 mm (2.5") of support deflection or out-of-level floor conditions.

"CAUTION": vertical wall jambs, swing closures, interlock of less than 50mm (2") between panels, or bottom seals allowing for less than 60 mm (2.5") of deflection will not be accepted.

TYPE "S" SUSPENSION

The suspension system shall be Type"S", steel precision bearing, reinforced nylon tired, 4 wheeled steel trolleys, running in heat treated, tempered, anodized aluminum track, connected to the support structure with pairs of .375" adjustable hanger rods spaced in accordance with the manufacturer’s recommendations.

"CAUTION": mill finished aluminum track, non-precision bearings, or steel tires will not be accepted.

TYPE "P" SUSPENSION

The suspension system shall be Type "P", all steel precision bearing, glass reinforced nylon tired, 4 wheeled steel trolleys, running in heat treated, tempered, anodized aluminum track, connected to the support structure with pairs of .375" adjustable hanger rods spaced in accordance with the manufacturer's recommendations.

"CAUTION": mill finished aluminum track, non-precision bearings, or steel tires will not be accepted.

TYPE "R" SUSPENSION

The suspension system shall be Type "R", all steel precision bearing, glass reinforced, nylon tired, Omni-directional trolleys, running in, heat treated, tempered, anodized aluminum, Omni-directional track, connected to the support structure with pairs of .375" adjustable hanger rods spaced in accordance with the manufacturer’s recommendations.

"CAUTION": mill finished aluminum track, non-precision bearings, or steel tires will not be accepted.

TYPE "O" SUSPENSION

The suspension system shall be Type "O", dual rotor, all steel precision bearing, glass reinforced, nylon tired, Omni-directional trolleys, running in, heat treated, tempered, anodized aluminum, Omni-directional track, connected to the support structure with pairs of .375" adjustable hanger rods spaced in accordance with the manufacturer’s recommendations.

"CAUTION": mill finished aluminum track, non-precision bearings, or steel tires will not be accepted.

TYPE "H" SUSPENSION

The suspension system shall be Type "H", all steel precision bearing, steel tired, 4 wheel trolleys, running on a Steel "I" Beam track c/w pre-painted steel soffit, connected to the support structure with pairs of .5" adjustable hanger rods and brackets spaced in accordance with the manufacturer’s recommendations.

"CAUTION": aluminum track, non-precision bearings, or nylon tires will not be accepted.

TYPE "G" SUSPENSION

The suspension system shall be Type "G", all steel precision bearing, steel tired, 4 wheeled trolleys, running on a Steel "I" beam track complete w/prepainted steel soffit, connected to the support structure with pairs of .5" adjustable hanger rods and brackets spaced in accordance with the manufacturer’s recommendations.

"CAUTION": aluminum track, non-precision bearings, or nylon tires will not be accepted.

"L-49" (STC 49) SOUND RATING

The Acoustical Performance Rating shall be "L-49", STC 49 as tested in an acoustical laboratory in accordance with ASTM E 90-90 413, and ISO 140/111 1978(E) with reporting to ASTM 413-94 and ISO 717

"CAUTION": non current sound tests (older than 1990), or class ratings will not be accepted.

"L-52" (STC 52) SOUND RATING

The Acoustical Performance Rating shall be "L-52", STC 52 as tested in an acoustical laboratory in accordance with ASTM E 90-90 413, and ISO 140/111 1978(E) with reporting to ASTM 413-94 and ISO 717

"CAUTION": non current sound tests (older than 1990), or class ratings will not be accepted.

"L-54" (STC 54) SOUND RATING

The Acoustical Performance Rating shall be "L-54", STC 54 as tested in an acoustical laboratory in accordance with ASTM E 90-90 413, and ISO 140/111 1978(E) with reporting to ASTM 413-94 and ISO 717

"CAUTION": non current sound tests (older than 1990), or class ratings will not be accepted.

remove this item 000

TYPE "PS" POCKET DOOR

OPERABLE WALL POCKET DOORS Type "PS" shown on the architectural drawings shall be manufactured by an Authorized Local Manufacturer, and supplied and installed under this section.

The construction, finish, trim, sound seals, and acoustical performance shall be exactly as specified for the operable partition panels, including sound seals, as specified for the partition panels.

"CAUTION": pocket doors of different construction, or without sound seals will not be accepted.

remove this item 000

TYPE "PO" POCKET DOOR

OPERABLE WALL POCKET DOORS Type "PO" shown on the architectural drawings shall be manufactured by an Authorized Local Manufacturer, and supplied and installed under this section.

The finish of the pocket doors and frames shall be by others, to match the finishes of the doors and frames specified for the room.

The construction, trim, sound seals, and acoustical performance shall be exactly as specified for the operable partition panels, including sound seals, as specified for the partition panels.

"CAUTION": pocket doors of different construction, or without sound seals will not be accepted.

remove this item 000

TYPE "MH" - HEAVY DUTY MAN DOOR

OPERABLE WALL PASS-THROUGH DOORS shall be Type "MH" shown on the architectural drawings shall be manufactured by an Authorized Local Manufacturer, and be of the same construction and finish, and same thickness as the panels. Each pass-through door shall be equipped with a roller-latch, and push / pull hardware for unrestricted egress. A retracting threshold is optional on manual partitions only.
remove this item 000

TYPE "MA" - ADA COMPLIANT MAN DOOR

OPERABLE WALL PASS-THROUGH DOORS shall be Type "MA" shown on the architectural drawings shall be manufactured by an Authorized Local Manufacturer, and be of the same construction and finish, and same thickness as the panels. Each pass-through door shall be sized to "ADA" requirements, and equipped with "ADA" compliant hardware. A retracting threshold is optional on manual partitions only.
remove this item 000

"CB" - CHALKBOARD

WRITING SURFACES shall be Type "CB" shown on the architectural drawings shall be manufactured as an integral part of the operable partition panels, and shall be porcelain-enameled steel, with all edges trimmed with matching molding, and no exposed fasteners.

Optional flush-mounted chalk trays shall be installed where indicated on the Architectural drawings.

"CAUTION": Surface applied writing surfaces will not be accepted.

remove this item 000

"MB" - MARKERBOARD

WRITING SURFACES shall be Type "MB" shown on the architectural drawings shall be manufactured as an integral part of the operable partition panels, and shall be porcelain-enameled steel, with all edges trimmed with matching molding, and no exposed fasteners.

Optional flush-mounted chalk trays shall be installed where indicated on the Architectural drawings.

"CAUTION": Surface applied writing surfaces will not be accepted.

remove this item 000

"TB" - TACKBOARD

TACK BOARDS shall be Type "TB" shown on the architectural drawings shall be manufactured as an integral part of the operable partition panels, and shall be natural cork, with all edges trimmed with matching molding, and no exposed fasteners.

Optional flush-mounted chalk trays shall be installed where indicated on the Architectural drawings.

"CAUTION": Surface applied writing surfaces will not be accepted.

remove this item 000

"VB" - VINYL BOARD

TACK BOARDS shall be Type "VB" shown on the architectural drawings shall be manufactured as an integral part of the operable partition panels, and shall be Natural Cork covered with vinyl. All edges shall be trimmed with matching molding, and no exposed fasteners.

Optional flush-mounted chalk trays shall be installed where indicated on the Architectural drawings.

"CAUTION": Surface applied writing surfaces will not be accepted.

Contact Information